, , 2,

: 545-569

+ 375

 

 

 
1; 6; 10

APPLICATION 
The cables are designed for power transmission and distribution in stationary equipment in net­works of 1; 6; 10 kV voltage


 –
 – , , “”
 – , , “”
 –
 –
 –  , «2», ,   

STRUCTURE
Core – stranded of copper wires
Insulation – paper impregnated with a viscous compound, for cables with index “”  – with a non-draining compound
Belt insulation – paper impregnated with a viscous compound, for cables with index “”  – with a non-draining compound
Screen – conducting paper tape
Sheath – extruded lead  
Protective cover –  crepe paper bedding, plastic tapes for cables with index “2”, two steel tapes, without external cover 
Cable type  – without protective cover


, , 
                                          6 10
  , , 2                    1; 6 10 
, °                           -50 +50

                                         15

SPECIFICATIONS
Nominal voltage, kV, 
for cable                                        6 or 10
for cables , , 2                 1; 6 or 10
Operating temperature, °                   -50  to +50
Minimal bending radius, 
cable diameters                                            15

  18410-73

The cables meet the requirements of national standard GOST 18410-73

 

, 2
Number of cores and cross section, mm2

,
Nominal external diameter, mm

,
2

,

,

2

1  
1 kV

6  
6 kV

10  
10 kV

1  
1 kV

6  
6 kV

10  
10 kV

6  
6 kV

10  
10 kV

3*35

3*35

24,9

30,7

34,6

25,5

31,7

35,5

25,2

29,1

3*50

3*50

27,1

32,9

36,8

27,7

33,9

37,7

26,5

30,5

3*70

3*70

29,8

36,0

39,9

30,4

36,5

40,4

30,5

34,4

3*95

3*95

33,2

39,3

43,1

33,8

39,8

43,6

33,8

37,6

3*120

3*120

36,5

41,9

45,8

37,1

42,4

46,3

36,4

40,3

3*150

3*150

39,9

45,4

49,4

40,5

45,9

49,8

39,9

43,8

3*185

3*185

43,6

48,4

52,4

44,2

48,8

52,8

42,6

46,6

3*240

3*240

48,0

52,0

55,9

48,6

52,6

56,5

47,2

51,1

3*35+1*16

-

27,3

-

-

-

-

-

-

-

3*50+1*25

-

29,6

-

-

-

-

-

-

-

3*70+1*35

-

31,7

-

-

-

-

-

-

-

3*95+1*50

-

36,0

-

-

-

-

-

-

-

3*120+1*70

-

39,1

-

-

-

-

-

-

-

3*150+1*70

-

42,5

-

-

-

-

-

-

-

3*185+1*95

-

46,3

-

-

-

-

-

-

-

4*35

-

28,1

-

-

-

-

-

-

-

4*50

-

30,7

-

-

-

-

-

-

-

4*70

-

34,5

-

-

-

-

-

-

-

4*95

-

38,4

-

-

-

-

-

-

-

4*120

-

42,3

-

-

-

-

-

-

-

4*150

-

43,7

-

-

-

-

-

-

-

4*185

-

47,1

-

-

-

-

-

-

-

4*240

-

52,6

-

-

-

-

-

-

-

 

   , 2 
Number of cores and cross section, mm2

  , / 
Design cable weight, kg/km

,
2

,

,

2

1  
1 kV

6  
6 kV

10  
10 kV

1  
1 kV

6  
6 kV

10  
10 kV

6  
6 kV

10  
10 kV

3*35

3*35

2386

31,84

3703

2424

3235

3754

2362

2771

3*50

3*50

2962

3777

4374

3002

3881

4435

2826

3316

3*70

3*70

3735

4700

5286

3779

4705

5289

3707

4183

3*95

3*95

4753

5750

6338

4801

5743

6357

4640

5147

3*120

3*120

5735

6713

7360

5787

6719

7364

5529

6068

3*150

3*150

6847

7910

8665

6903

7948

8666

6646

7256

3*185

3*185

8231

9282

10086

8292

9174

9987

7752

8453

3*240

3*240

10142

11061

11865

10209

11151

11961

9676

10381

3*35+1*16

-

2604

-

-

-

-

-

-

-

3*50+1*25

-

3217

-

-

-

-

-

-

-

3*70+1*35

-

3932

-

-

-

-

-

-

-

3*95+1*50

-

5033

-

-

-

-

-

-

-

3*120+1*70

-

5982

-

-

-

-

-

-

-

3*150+1*70

-

7204

-

-

-

-

-

-

-

3*185+1*95

-

8556

-

-

-

-

-

-

-

4*35

-

3012

-

-

-

-

-

-

-

4*50

-

3771

-

-

-

-

-

-

-

4*70

-

4835

-

-

-

-

-

-

-

4*95

-

6088

-

-

-

-

-

-

-

4*120

-

7451

-

-

-

-

-

-

-

4*150

-

8644

-

-

-

-

-

-

-

4*185

-

10230

-

-

-

-

-

-

-

4*240

-

12811

-

-

-

-

-

-

-

3.7

  • 157

+ 375

:

220033, , ., , - , 75-1

, EnergoBelarus.by

EnergoBelarus.by .

, , 2, , . . .

EnergoBelarus.by .

, , info@energobelarus.by.